 100 kV NEW MICROFOCUS X-RAY SOURCE
L7901-01
FEATURES
G Focal Spot Size: 5 m (at 4 W) G Easy Handling
Providing 5m focal spot size, for the sealed-off type X-ray source with built-in power supply. It gives a clear clairvoyance image despite of higher magnification ratio. Convenient handling (with no high voltage wiring) since the air cooled X-ray source and the high voltage power supply are in one package.
APPLICATIONS
G X-ray Non-destructive Test
* Printed Circuits * Semiconductor Devices * Soldered Parts * Combinated Materials * New materials * Electronic Components * Ceramics * Rubbers * Plastics * Die casting
G Continuous Operation
It allows continuous maximum output, 100kV and 100A, operation. It is automatically operable from external control since it has a built-in RS-232C interface.
G Built-in External Control Function
G Multilayer Printed Circuit Board X-ray Inspection*Drilling Instrument G Industrial On-line Process Control and Measurement G Industrial X-ray Computer Tomography System
SPECIFICATIONS
GGENERAL
Parameter Target Voltage Target Current Maximum Output Power Focal Spot Size Beam Angle Minimum Distance Focus/Object Environmental X-ray Dose Leakage Operation
NOTE: a In the range of output (= Tube voltage x Tube current) less than 10 W
Value/Description 20 to 100 0 to 250a 10 (isowatts) 7 (5 m at 4 W) 39 9.5 1 Continuous
Unit kV A W m degree mm mSv/h Max. --
IX-RAY TUBE UNIT
Parameter X-ray Tube Cooling Method Window Material Target Material Cathode Material Window Position High Voltage Power Supply Operation /Storage Temperature Operation/Storage Humidity Weight Description Sealed Type Forced Air Cooling Beryllium (150 mt) Tungsten Dispenser Cathode End-window Built-in Type +10 to +40 C / 0 to +50 C 85 % RH Max.a Approx. 6 kg
IX-RAY CONTROL UNIT
Parameter Function Protection External Control Operation /Storage Temperature Operation/Storage Humidity Power Consumption Inter Voltage Installation Method Weight Description Target Voltage/Current Pre-set, Auto Warm-up Safety Interlock RS-232C 0 to +40 C 85 % RH Max.a 200 W Max. 24 Vdc Designed for both bench-top and rack mounting Approx. 5 kg
NOTE: a Without moisture condensation.
100 KV MICROFOCUS X-RAY SOURCE
DIMENSIONAL OUTLINE (Unit: mm)
X-RAY TUBE UNIT
320.5 2.0
X-RAY FOCAL SPOT 39 9.5 24 135 2 4-M3 L=4 40 MIN. 100 52 16.5 17 290.0 0.5 30 X-RAY UNIT INSTALLATION SCREW HOLES 4-M4 D5
TLSOA0063EA
107 2
66 36.5 70 5 34
X-RAY CONTROL UNIT
100 MIN.
X-RAY MODE
X-RAY OFF
VOLTAGE
CURRENT
X - R AY 1 0 0 C O N T R O L U N I T
OVER ERROR
110.0 0.5
76 31
STANDBY
CONTROL
AGING X-RAY ON PRE-SET
CONTROL
PRE-SET
OPERATE
ON OFF REMOTE
INTER LOCK
9
426 2 482 2
9 12
50
kV
A
99 2
40
300 2
30
INTERCONNECTION CABLE CONNECTOR DIA 33 mm MAX.
X-RAY REMOTE AGING SIGNAL INTER LOCK 1 INTER LOCK 2 OUTPUT
RS-232C
I D E N T I F I C AT I O N P L AT E
LABEL
TLSOA0064EA
100 KV MICROFOCUS X-RAY SOURCE
RELATED PRODUCTS
X-RAY IMAGE INTENSIFIER CAMERA UNIT C7716, C7716-10
The C7716 series X-ray image intensifier (I. I.) camera unit now offers greatly improved X-ray detection efficiency even at low energy levels. This improvement stems primarily from a built-in X-ray image intensifier having an extremely thin aluminum input window. Its thickness is only 0.3mm or less, virtually at the limit of present technology providing excellent X-ray transmit-tance and low scattering. The results are sharp, clear, high-quality images taken at low energy X-ray levels down to several keV which penetrate plastic (PET) materials.
X-RAY IMAGE INTENSIFIER CAMERA UNIT C7876, C7876-10
The C7876 is an X-ray image intensifier camera unit ideal for non-destructive inspection of light-element materials and radiation imaging at low-energy X-ray levels. The C7876 remarkably improves X-ray transmittance at low-energy X-ray levels by using a beryllium window instead of the aluminum window currently used for most X-ray image intensifiers. The result is a sharp and clear, high-contrast image taken in real time even at low energy X-ray levels down to a few keV.
! PRE-CAUTION TO USE
1. X-ray emitted from this device is harmful for human body. And it should be necessary for the operator to protect himself/herself from it. 2. During an operation, the X-ray tube unit should be installed in the X-ray shielded cabinet in order to avoid any X-ray leakage. Also the safety interlock system in X-ray control unit should be always used in order to avoid any misoperation.
# WARRANTY PERIOD
This device is guaranteed for one and a half years from data of purchase or 5000 hours of operation, whichever comes first. The warranty extends only to replacement of the products. The warranty does not cover damage due to misuse or natural calamity.
*
This product(s) conforms to the EMC directive (89/336/EEC) of the European Union.
* To meet FDA standards, the Interlock-1 circuit incorporates a relay that shuts off the X-ray generation power supply circuit if the circuit is open.
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. (c)2000 Hamamatsu Photonics K.K
HOMEPAGE URL http://www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Electron Tube Center 314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: usa@hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de France: Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: infos@hamamatsu.fr United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Smidesvagen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se TLSO1038E03 Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: info@hamamatsu.it
DEC. 2001 IP Printed in Japan (1000)


▲Up To Search▲   

 
Price & Availability of L7901-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X